From: Rei.Odaira@... Date: 2014-05-29T09:52:48+00:00 Subject: [ruby-core:62836] [ruby-trunk - Bug #9878] [Open] ruby_signal() should return either sa_sigaction or sa_handler, depending on SA_SIGINFO Issue #9878 has been reported by Rei Odaira. ---------------------------------------- Bug #9878: ruby_signal() should return either sa_sigaction or sa_handler, depending on SA_SIGINFO https://bugs.ruby-lang.org/issues/9878 * Author: Rei Odaira * Status: Open * Priority: Normal * Assignee: * Category: * Target version: * ruby -v: ruby 2.2.0dev (2014-05-29 trunk 46222) [x86_64-linux] * Backport: 2.0.0: UNKNOWN, 2.1: UNKNOWN ---------------------------------------- `ruby_signa()` in signal.c returns old.sa_handler, but it should return either old.sa_sigaction or old.sa_handler, depending on whether SA_SIGINFO is set in old.sa_flags. ~~~ --- signal.c (revision 46222) +++ signal.c (working copy) @@ -595,7 +595,10 @@ rb_bug_errno("sigaction", errno); } } - return old.sa_handler; + if (old.sa_flags & SA_SIGINFO) + return (sighandler_t)old.sa_sigaction; + else + return old.sa_handler; } sighandler_t ~~~ The original code happens to be correct on the environments where sa_handler and sa_sigaction are union, but it is not guaranteed in general. (Actually, they are not union on z/OS.) -- https://bugs.ruby-lang.org/